Product Type: HC--SR501 Body Sensor Module
Operating voltage range: DC 4.5-20V
Quiescent Current: <50uA
Level output: High 3.3 V /Low 0V
Trigger: L can not be repeated trigger/H can be repeated trigger(Default repeated trigger)
Delay time: 5-200S(adjustable) the range is (0.xx second to tens of second)
Block time: 2.5S(default)Can be made a range(0.xx to tens of seconds
Board Dimensions: 32mm*24mm
Angle Sensor: <100 ° cone angle
Operation Temp: -15- 70 degrees
Lens size sensor: Diameter:23mm(Default)
Features:
1. the automatic sensor: to enter the sensor output range is high, people leave the sensor range of the automatic
delay off high, output low.
2. the photosensitive control (optional, factory is not set) may set the photosensitive control during the day or
light intensity without induction.
3. the temperature compensation (optional, factory is not set): In the summer when the ambient temperature rises
to 30 ~ 32 °, slightly shorter detection range, temperature compensation can be used as a performance compensation.
4. two trigger mode: (can be selected by jumpers)
a) can not repeat the trigger: the sensor output high, the delay time is over, the output will automatically
become low from high;
b) repeatable trigger: the sensor output high after the delay period, if the human body in its sensing range
activities, its output will remain high until after the delay will be left high to low (sensor module review
Measured activities of each body will be automatically extended after a delay time, and the final event of
the delay time Starting point of time).
5. with induction blocking time (the default setting: 2.5S block time): sensor module, after each sensor output
(high change Into a low level),you can set up a blockade followed by time period, in this time period the sensor
does not accept any sensor signal. This feature can have a "sensor output time" and "blocking time" the interval
between the work produced can be applied to detect the interval Products; also inhibit this function during load
switching for a variety of interference. (This time can be set at zero seconds - Tens of seconds).
6. the working voltage range: the default voltage DC4.5V-20V.
7. micro-power consumption: static current "50 microamps, especially for battery-powered automatic control products.
8. the output high level signals: types of circuits can be easily and docking.
Instructions:
1. Sensing module for about a minute after power initialization time, during the interval to the output module
0-3 times a minute in standby mode.
2. Should avoid direct lighting such as interference sources close the surface of the lens module so as to avoid the
introduction of interference signal generator malfunction; use of the environment to avoid the flow of the wind, the
wind sensor will also cause interference.
3. Sensor module using a dual probe, the probe's window is rectangular, dual (A per B million) in the direction of
the ends of long, when the body passed from left to right or right to left when the reach the dual IR time, distance
difference, the greater the difference, more sensitive sensors, when the body from the front to the probe or from top
to bottom or from bottom to top direction passing, dual IR not detected changes in the distance, no difference value,
the sensor insensitive or does not work; so the sensors should be installed dual direction of the probe with human
activities as much as possible parallel to the direction of maximum to ensure that the body has been passed by the
dual sensor probe. To increase the sensing range of angles, the module using a circular lens, the probe also makes sense
on all four sides, but still higher than the upper and lower left and right direction of sensing range, sensitivity and
strong, still as far as possible by the above installation requirements.VCC, trig (control side), echo (receiving end), GND
4. Dimensions and Adjustment:
Note: The potentiometer clockwise to adjust the distance, sensing range increases (about 7 meters), on the contrary,
sensing range decreases (about 3 meters).Delay adjustment potentiometer clockwise rotation, sensor delay longer (about 300S),
the other hand, induction by the short delay (about 5S).
5. Applications
a) Security Products
b) the human body sensors toys
c) the human body sensor lighting
d) industrial automation and control, etc.
It can automatically and quickly open various types of incandescent, fluorescent lamps, buzzer, automatic doors,
electric fans,automatic washing machine and dryer Machines and other devices,is a hightech products. Especially
suitable for enterprises, hotels, shopping malls, warehouses and family aisles, corridors and other sensitive
Sense of region, or for the security zone automatic lighting, lighting and alarm systems.
Датчик движения HC-SR501
При вхождении человека в зону обзора датчика фиксируется присутствие. Принцип работы модуля HC-SR501 заключается в регистрации инфракрасного излучения от подвижного объекта. Чувствительный элемент - пироэлектрический датчик 500BP. Он состоит из двух элементов заключенных в одном корпусе. Чувствительный элемент закрыт белым куполом - линзой Френеля. Особенности линзы Френеля таковы, что инфракрасное излучение от подвижного объекта попадает сначала на один элемент датчика 500BP, затем на другой. Электроника модуля HC-SR501 регистрирует поочередное поступление сигналов от двух элементов из состава 500BP и при фиксации движения выходная цепь модуля формирует логический сигнал.
Датчик присутствия HC-SR501 применяется в охранных системах, включении вентиляции, позволяет управлять освещением помещений без окон. Совместно с фотореле примется в управлении освещением дворов и улиц. Интересные результаты можно получить при управлении с помощью датчика фотоаппаратом или видеокамерой.
PIR-sensor переводится с английского как Pyroelectric (Passive) InfraRed sensor -пироэлектрический (пассивный) инфракрасный сенсор.
Основные параметры модуля HC-SR501
Напряжение питания: DC 4.5- 20V
Ток на OUT: <60uA
Напряжение на выходе: Высокие и низкие уровни в 3.3V TTL логике
Дистанция обнаружения: 3 - 7м (настраивается), по умолчанию 7 м
Угол обнаружения: до 110°, на расстоянии 7 м 120°
Длительность импульса при обнаружении: 5 - 200сек.(настраивается)
Время блокировки до следующего замера: 2.5сек. (но можно изменить заменой SMD-резисторов)
Рабочая температура: -20 +80°C
Режим работы: L - одиночный захват, H - повторяемые измерения
Размеры: 3.2см x 2.4см x 2.8см
Режим работы модуля задается перемычкой. Есть два режима - режим H и режим L.
Режим H - в этом режиме при срабатывании датчика несколько раз подряд на его выходе (на OUT) остается высокий логический уровень.
Режим L - в этом режиме на выходе при каждом срабатывании датчика появляется отдельный импульс.
Прибор готов к работе через минуту после подачи питания. За это время происходит автоматическая калибровка. При выборе места установки следует избегать ориентации датчика на открытые источники света. Устанавливать датчик присутствия HC-SR501 следует так, чтобы перемещение подвижного объекта происходило вдоль плоскости платы модуля.
Не стоит располагать PIR-датчики в местах, где быстро меняется температура. Это приведет к тому, что датчик не сможет обнаруживать появление человека в контролируемой зоне, и будет много ложных срабатываний.
К микроконтроллерам (ну или другим микросхемам) модуль лучше (хотя и необязательно) подключать через транзистор и подтягивающий резистор на 10
TAGS:sensor HCSR501 infraqirmizi hereket sensoru ,infraqırmızı hərəkət sensoru
IC use: PIR (Passive Infrared) Controller BISS0001 16pin; 30mA Low Power LDO SOT89 7133-1 3pin